Last Updated: November 11, 2026
Building in a Bushfire Prone Area (BPA) in Victoria means your portable building must meet specific bushfire construction requirements. The level of protection required depends on your property’s Bushfire Attack Level (BAL) rating, which determines how the building must be constructed to resist ember attack, radiant heat, and direct flame contact.
For how BAL levels affect a kit home rather than a portable building, see what BAL rating you need for a kit home in a bushfire zone.
This guide explains BAL ratings, what they mean for your portable building, and how to ensure compliance when building in bushfire-affected areas.
What Is a BAL Rating?
The Bushfire Attack Level (BAL) is a measurement of the potential severity of bushfire attack on a building. It considers factors including the type and density of surrounding vegetation, the slope of the land, the distance from the vegetation to the building, and the Fire Danger Index for the region.
BAL ratings are determined by a qualified BAL assessor or bushfire planning consultant. This assessment is required as part of any building permit application in a designated Bushfire Prone Area.
BAL Rating Levels Explained
BAL-LOW: There is insufficient risk to warrant specific construction requirements beyond normal building standards. This applies to properties with minimal vegetation exposure or adequate separation from bushfire hazards.
BAL-12.5: The building may be subject to ember attack and a radiant heat flux not exceeding 12.5 kilowatts per square metre. This is the lowest level requiring specific bushfire construction measures. The extent to which standard portable buildings can meet this level depends on their existing construction specifications and the modifications required.
BAL-19: Increased ember attack risk and radiant heat exposure up to 19 kW/m². Requires enhanced protection to windows, doors, and external surfaces. The cost impact on construction depends on the specific upgrades needed for the building design.
BAL-29: Significant ember attack and radiant heat up to 29 kW/m², with increased likelihood of exposure to burning debris and flame contact from nearby vegetation. This is the highest level at which most standard construction methods remain viable. The extent of construction upgrades required depends on the building’s base specifications and design.
BAL-40: Very high radiant heat exposure up to 40 kW/m² with direct exposure to flames possible from nearby burning vegetation. Construction requirements depend on the specific design and materials selected to meet the performance criteria for this level.
BAL-FZ (Flame Zone): Direct exposure to flames from fire front and significant heat flux exceeding 40 kW/m². The most stringent requirements apply, and many standard construction methods are not suitable. Building in FZ areas often requires specialist design.
Construction Requirements by BAL Level
BAL-12.5 Construction: At this level, your portable building needs ember protection to all openings including mesh screens on vents and weep holes, non-combustible materials in contact with ground, and appropriate glazing. Whether Colorbond-clad portable buildings meet these requirements depends on their specific construction details and the addition of ember screening.
BAL-19 Construction: Additional requirements include ember guard mesh on all openings, upgraded window protection, and non-combustible external surfaces below floor level. Door hardware and seals must be specified to resist ember entry.
BAL-29 Construction: This level requires substantial upgrades. Windows need BAL-29 rated glazing, all external surfaces must be non-combustible, sarking must be non-combustible, and all external joints sealed against ember entry. Decking and stairs must be non-combustible materials.
BAL-40 and BAL-FZ: These levels require specialist construction methods including fire-rated wall systems, BAL-40/FZ rated windows and doors, and comprehensive ember sealing throughout. Many standard portable building construction methods cannot achieve these ratings, and purpose-designed solutions are often required.
POMO Bushfire Rated Buildings
POMO Portable Modular manufactures buildings to BAL-29 as standard for bushfire-prone areas. Our construction includes TRUECORE steel frames (non-combustible), Colorbond steel cladding (non-combustible), fire-rated insulation, metal-framed windows with BAL-rated glazing, compliant ember screens on all openings, non-combustible subfloor systems, and sealed construction to prevent ember entry.
For BAL-40 and BAL-FZ sites, we can work with bushfire consultants to develop compliant designs, though these require project-specific engineering and the cost impact depends on the specific design requirements.
Cost Impact of BAL Ratings
Building to higher BAL ratings increases construction costs. Here’s what to expect:
BAL-12.5: The cost impact depends on the specific ember screening and minor upgrades required for the building design.
BAL-19: The cost increase depends on the specific screening, door hardware, and glazing upgrades required for the building design.
BAL-29: The cost increase depends on the specific rated windows and doors, sealing requirements, and non-combustible decking or stairs required for the building design.
BAL-40: The cost increase depends on the specialist materials required throughout the building design.
BAL-FZ: Project-specific pricing required. The cost increase depends on the specific design requirements and whether construction is viable at all.
Getting Your BAL Assessment
A BAL assessment must be completed by a qualified assessor before your building permit application. The assessment considers the vegetation within 150 metres of your building site (including neighbouring properties), the slope of land between vegetation and the building, the classified vegetation type, and the Fire Danger Index for your region.
BAL assessment costs depend on site complexity. Some councils require updated assessments if the report is more than 12 months old at the time of building permit application.
You can sometimes reduce your BAL rating by vegetation management. Removing or reducing vegetation within the assessment area, particularly closer to the building site, can lower the BAL rating. However, you need council approval for vegetation removal, and maintaining the reduced vegetation level becomes an ongoing obligation attached to the property.
Landscaping and Defendable Space
Beyond the building itself, creating defendable space around your portable building improves bushfire safety and may be required by your planning permit. A defendable space typically includes an inner zone clear of vegetation and combustible materials, an outer zone with reduced vegetation and cleared of accumulated debris, and adequate vehicle access for firefighting equipment.
Consider these landscaping principles when placing your portable building: position away from steep downhill slopes where fire travels fastest, maintain clearance from trees, especially eucalypts, avoid placement where wind could funnel fire toward the building, and ensure adequate water supply access for firefighting.
Insurance Considerations
Buildings in bushfire-prone areas typically attract higher insurance premiums. However, buildings constructed to appropriate BAL standards may qualify for better rates than non-compliant structures. Keep all documentation of your BAL rating, construction specifications, and compliance certificates for insurance purposes.
Some insurers may decline coverage or impose conditions for buildings in very high-risk areas (BAL-40 and FZ). Check insurance availability before committing to building on high-risk sites.
Getting Started
If you’re planning a portable building in a bushfire-prone area, the process typically involves checking whether your property is in a designated BPA (check with your council or the Victorian Government’s planning maps), getting a BAL assessment from a qualified assessor, confirming the construction requirements for your BAL rating, and specifying the building accordingly when requesting quotes.
POMO Portable Modular can discuss construction standards for bushfire areas. We can work with your BAL assessor to ensure compliance.
Contact POMO to discuss your bushfire-rated portable building requirements.